Détails sur le produit:
Contact
Causez Maintenant
|
| Nom: | Acier tubulaire galvanisé à chaud 5G Radio antenne Télécommunication Mast Communication Télécom Guye | Norme de galvanisation: | Pour l'utilisation de la méthode ASTMA123 |
|---|---|---|---|
| Matériel: | ASTM A36 Gr50 | Écrous et boulons: | GrGrade 6.8/4.8 |
| Hauteur: | 8-100m | Vitesse du vent: | >=60m/s |
| Durée de vie: | plus de 20 ans | Structure de connexion: | raccord à bride/raccord à boulons |
| Traitement de surface: | Galvanisé à chaud | soudage: | AWS D 1,1 |
| couleur: | Couleur Stardand de RAL | ||
| Mettre en évidence: | galvanized lattice steel telecom mast,guyed wire tower for 5G wifi,microwave telecommunication signal mast with warranty |
||
JIAYAO CO., LTD.
1.Specifications
| Design | ||
| 1. Design Code | ANSI/TIA-222-G/H/F | |
| Structure Steel | ||
| 2. Grade | Mild Steel | High Tensile Steel |
| GB/T 700:Q235B, Q235C,Q235D | GB/T1591:Q355B, Q355C,Q355D | |
| ASTM A36 | ASTM A572 Gr50 | |
| EN10025: S235JR, S235J0,S235J2 | EN10025: S355JR, S355J0,S355J2 | |
| 3. Design Wind Speed | Up to 250 km/h | |
| 4. Allowable deflection | 0.5 ~1.0 degree @ operational speed | |
| 5. Tension strength (Mpa) | 360~510 | 470~630 |
| 6. Yield strength (t≤16mm) (Mpa) | 355 | 235 |
| 7. Elongation (%) | 20 | 24 |
| 8. Impact strength KV (J) | 27(20°C)---Q235B(S235JR) | 27(20°C)---Q345B(S355JR) |
| 27(0°C)---Q235C(S235J0) | 27(0°C)---Q345C(S355J0) | |
| 27(-20°C)---Q235D(S235J2) | 27(-20°C)---Q345D(S355J2) | |
| Bolts & Nuts | ||
| 9. Grade | Grade 4.8, 6.8, 8.8 | |
| 10. Standards for mechanical properties | ||
| 10.1 Bolts | ISO 898-1 | |
| 10.2 Nuts | ISO 898-2 | |
| 10.3 Washers | ISO 6507-1 | |
| 11. Standards for Dimensions | ||
| 11.1 Bolts | DIN7990, DIN931, DIN933 | |
| 11.2 Nuts | ISO4032, ISO4034 | |
| 11.3 Washers | DIN7989, DIN127B, ISO7091 | |
| Welding | ||
| 12. Method | CO2 Shielded Arc Welding & Submerged Arc Welding(SAW) | |
| 13. Standard | AWS D1.1 | |
| Marking | ||
| 14. Method of marking of the members | Hydraulic Press Stamping | |
| Galvanizing | ||
| 15. Galvanization standard of steel sections | ISO 1461 or ASTM A123 | |
| 16. Galvanization standard of bolts and nuts | ISO 1461 or ASTM A153 | |
What is the tower boday of guyed wire tower?
How to mount antenna on the guyed wire tower?
What is the Anti Climbing Device on the guyed wire tower?
How to connect guyed wire and guyed wire tower?
How to connect guyed wire and guyed anchor bolt?
Please Click Here For More Information!!!!!!
1. Is the tower's structure unitary?
No, we can design and produce it as customer's request.
4. How long does the service life for steel tower?
We can assured 20-30 years’service life.
Personne à contacter: Eric.Jia
Téléphone: +86-13903181586